SINGLE TURN HIGH CURRENT TRANSFORMER
OUTPUT 2.75 / 2.88 / 3.02 / 5.50 VAC, 5500 AMPS
30.25 KVA, P/N 19726
Specifications:
-
- High Current Transformer: 30.25 KVA, 1 PH, 60 Hz, P/N 19726
- Primary (1 to 5): 220 VAC, 138 Amps
- Secondary: 2.75 / 2.88 / 3.02 / 5.50 VAC, 5500 Amps, 1 turn of customer supplied cable (4″ x 1″ copper bus bar)
- Turn ratio: 80 to 1
- If 220 VAC is connected to (1, 5), the Output is 2.75 VAC
- If 220 VAC is connected to (1, 4), the Output is 2.88 VAC
- If 220 VAC is connected to (1, 3), the Output is 3.02 VAC
- If 220 VAC is connected to (1, 2), the Output is 5.50 VAC
- The window provided for customer cable or bus bar: 4.0” x 5.0”
- Loose primary to secondary will result in coupling voltage losses
- Primary copper bus bars are 1/8” x 5/8” with one hole
- Copper Windings
- Approvals: None
- Open Core & Coil: 25″W x 15.5″H x 15”D approximately
- Estimated weight: 500 lbs
The photo of the transformer is shown below:
The schematic diagram of the transformer is shown below:
To discuss your specific application, please call us at (714) 624-4740, or send us an email at quote@lcmagnetics.com.