SINGLE PHASE HIGH CURRENT TRANSFORMER
6 KVA, OUTPUT 4 VAC, 1500 AMPS, P/N 19643

Specifications:

  • High Current Transformer, 6 KVA, 1 PH, 60 Hz, P/N 19643
  • Primary: 240 VAC, 25 Amps
  • Secondary: 4 VAC, 1500 Amps
  • Copper windings.
  • Approvals: None
  • Two J Thermocouples are installed inside the transformer. One in the primary winding and one in the secondary winding.
  • Primary copper bus bars are 1/8″ x 5/8″ with one hole
  • Secondary copper bus bars are 3/8” x 4” with one hole
  • Open core & coil: 9”W x 18”D x 8.25”H.
  • Weight: 150 lbs. approx.

The photo of the transformer is shown below:

 

 

 

The schematic diagram is shown below:

 

 

To discuss your specific application, please call us at (714) 624-4740, or send us an email at quote@lcmagnetics.com.