(714) 624-4740 quote@lcmagnetics.com

INDUCTION HEATING TRANSFORMER, 6.68 KVA, 3000 HZ TO 4000 HZ, P/N 19618A

Specifications:

  • Ferrite Core Transformer, 6.68 KVA, 1 PH, P/N 19618A
  • Center Frequency: 3500 Hz, Range: 3000 Hz to 4000 Hz
  • Primary (1, 2): 106 VAC, 63 Amps
  • Secondary (3, 4): 65 VAC, 103 Amps
  • Copper windings. Approvals: None
  • Primary copper bus bars are 1/8” x 5/8” with one hole
  • Secondary copper bus bars are 1/4” x 1” with one hole
  • Mounting feet: None
  • Open core & coil: 8”W x 9”H x 7”D
  • Estimated weight: 42 lbs.

The photo of the Ferrite Core transformer is shown below:

 

 

The schematic diagram of the transformer is shown below:

 

 

To discuss your specific application, please call us at (714) 624-4740, or send us an email at quote@lcmagnetics.com.