FERRITE CORE TRANSFORMER, 13.36 KVA
3000 Hz TO 4000 Hz, P/N 19618B
Specifications:
- Ferrite Core Transformer, 13.36 KVA, 1 PH, P/N 19618B
- Center Frequency: 3500 Hz, Range: 3000 Hz to 4000 Hz
- Primary (1, 2): 212 VAC, 63 Amps
- Secondary (3, 4): 129.2 VAC, 103 Amps
- Copper windings. Approvals: None
- Primary copper bus bars are 1/8” x 5/8” with one hole
- Secondary copper bus bars are 1/4” x 1” with one hole
- Mounting feet: None
- Open core & coil: 8.125”W x 9.00”H x 7.50”D. Estimated weight: 42 lbs.
The photo of the Ferrite Core transformer is shown below:
The schematic diagram of the transformer is shown below:
To discuss your specific application, please call us at (714) 624-4740, or send us an email at quote@lcmagnetics.com.