EXTRA ROBUST DUTY TRANSFORMERS
We are REPLACEMENT Transformer Specialists
We are OBSOLETE Transformer Specialists
We are URGENT Transformer Specialists
How can we help?
L/C Magnetics Team, celebrating 34 years in business
Our new email address is quote@lcmagnetics.com
L/C MAGNETICS Transformer Company Overview
With over thirty years of transformer experience and our long standing commitment to quality and customer service, L/C MAGNETICS Transformer will design and build the transformer that is right for your specific application.
L/C MAGNETICS provides custom built dry and or liquid filled transformers for the industry, designed by industry leading, experienced engineers for the unique requirements of Robust Duty transformers. Our people, knowledge, and experience can provide a reliable, cost-effective transformer that will provide years of trouble free service.
Application
Robust Duty transformers are critical components in the traction chain, affecting both train performance and operator services. L/C MAGNETICS supplies traction substation transformers for all applications:
- High-speed, commuter and regional trains.
- Transit/Traction- In general, electricity is distributed along track as DC current. Converted to AC on trains to drive motors. 500VDC – 1500VDC is typical range.
These transformers are typically located in either indoor or outdoor traction substations.
Advantages with L/C MAGNETICS
A highly experienced and trained engineering staff (ALL IN-HOUSE) for the design and manufacturing of standard and highly specialized products.
- Product offerings in both dry type and liquid filled to meet your specific demands.
- 220°C Nomex insulation for Dry-Type Transformers • Self-Cooled or Forced Air Cooled
- Low Voltage and Medium Voltage solutions.
- All processes done in-house at our own UL, CUL, CSA and ISO 9001-2015 certified facilities.
- Shortest lead times in the industry.
- Every process is done under roof
Our Capabilities
- 10 KVA – 5 MVA, single phase transformers
- Dry type or Liquid filled
- 10 KVA – 10 MVA, three-phase transformers
- 120 volt – 34,500 volt range
- 10 KV – 250 KV Basic Impulse Level (BIL)
Features
- Compliance with IEEE 1653.1-2017
- Typically Traction transformers experience a high number of short circuits while in operations and transformers may be exposed to 10-20 times their rated current.
- Traction- Typically the temperature rise is determined by the transformer overload rating defined in IEEE P1653.2. Overloads are chosen to allow trains to function at peak passenger loads with failed substations in the system.
-
Light Robust duty (150% for 2 hrs.)
-
- 100 % rated load cycle of the rectifier current in ampere continuously followed by either
- 150 % of rated load cycle of the rectifier current in ampere for 2 hours or
- 200% of rated load cycle of the rectifier current in ampere for 1 minute following 100% rated load
-
Heavy Robust duty (150% for 2hrs)
- 100% rated load cycle of the rectifier current in ampere continuously followed by either.
- 150% of rated load cycle of the rectifier current in ampere for 2 hours or
- 300% of rated load cycle of the rectifier current in ampere for 1 minute following 100% rated load
-
Extra-Heavy Robust duty (162 % rms for 2 hours)
- 100 % rated load cycle of the rectifier current in ampere continuously followed by
- 150% of rated load cycle of the rectifier current in ampere for 2 hours followed by
- 300% of rated load cycle of the rectifier current in ampere for 5 equally spaced periods, each 1 minute
- Followed by final 450% of rated load cycle of the rectifier current for 15 seconds.
Testing and Quality Control
L/C MAGNETICS Transformer tests every Robust Duty Transformer to satisfy the requirements of IEEE 1653.1. Our testing equipment ensures the highest quality transformers that meet all IEEE, and NEMA standards. We also offer customer witness testing on individual transformers and we have the capability of providing a range of design tests and optional tests such as impulse, partial discharge, temperature rise, sound level, and others.
Tests specific to Robust Duty include:
- Commutating Impedance.
- Losses- Guaranteed losses are based only on sinusoidal rated transformer current (no harmonics). Many rectifier types have special measurement procedure as per C57.18.10.
- Thermal Tests- Measured with losses equal to sinusoidal current losses corrected (increased) for harmonic load currents.
THE BETTER CHOICE!
L/C MAGNETICS is a leader in the transformer industry and a premiere manufacturer capable of fulfilling the most demanding applications. No one can provide a wider range of products and solutions than L/C MAGNETICS!
Celebrating 34 years in business
Send us an email for a Free Quote.
quote@lcmagnetics.com
Tel: (714) 624 4740
Our engineers will respond within the hour.
L/C Magnetics Inc. is a manufacturer, re-seller and distributor of transformer products from 0.1 KVA to 50 MVA, dry type
Our CEHCO division (www.cehco.com) builds DC Rectifiers, Transformer Rectifier Assemblies and Custom Power Supplies.
Replacement extra robust duty transformers, Hard to find extra robust duty transformers, Extra robust duty transformers for rectifiers, Extra robust duty transformers, extra heavy duty transformers, heavy duty industrial transformers, extra durable transformers, robust duty power transformers, high capacity duty transformers, heavy-duty transformer design, custom heavy-duty transformers, industrial robust transformers, extra rugged transformers, heavy-duty transformer solutions