Secondary Center Tap Output 0.05 KVA

Specifications:

  • Secondary Center Tap Output Transformer, 0.05 KVA, 1 PH, 60 Hz, P/N 9B-19629
  • Primary (1, 2, 3): 0 / 110 / 120 VAC, 0.42 Amps
  • Secondary (4, 5, 6): -16 / 0 / 16 VAC, 1.5 Amps
  • Copper windings
  • Primary and secondary connections are solder lugs
  • Open core & coil: 3″W x 2.5″H x 3″D
  • Approvals: None
  • Estimated weight: 3 lbs.

The photo of the transformer is shown below:

 

 

The schematic diagram is shown below:

 

 

To discuss your specific application, please call us at (714) 624-4740, or send us an email at quote@lcmagnetics.com.

Secondary Center Tap Output 0.05 KVA, Secondary Center Tap Transformer 0.05 KVA, High efficiency Secondary Center Tap Transformer 0.05 KVA, Custom Secondary Center Tap Transformer 0.05 KVA, Center Tap Transformer with Secondary Output of 0.05 KVA, 60 Hz Transformer with Secondary Center Tap Output of 0.05 KVA, 9B-19629 Secondary Center Tap Transformer, 0/110/120 VAC Primary Secondary Center Tap Transformer 0.05 KVA, Secondary Center Tap Transformer -16/0/16 VAC, Secondary Center Tap Transformer with Solder Lugs, Small Secondary Center Tap Transformer 0.05 KVA, Secondary Center Tap Output 0.05 KVA Innovation, Secondary Center Tap Output 0.05 KVA Durability, Secondary Center Tap Output 0.05 KVA Installation Guides, Secondary Center Tap Output 0.05 KVA Components, Secondary Center Tap Output 0.05 KVA Load Management, Secondary Center Tap Output 0.05 KVA Maintenance Programs, Secondary Center Tap Output 0.05 KVA Environmentally Friendly Solutions, Secondary Center Tap Output 0.05 KVA Diagnostics, Secondary Center Tap Output 0.05 KVA Lifecycle, Secondary Center Tap Output 0.05 KVA Projects, Secondary Center Tap Output 0.05 KVA Replacement, Secondary Center Tap Output 0.05 KVA Controls, Secondary Center Tap Output 0.05 KVA Cooling Systems, Secondary Center Tap Output 0.05 KVA Simulation, Secondary Center Tap Output 0.05 KVA Optimization, Secondary Center Tap Output 0.05 KVA Cost Analysis, Secondary Center Tap Output 0.05 KVA Energy Efficiency, Secondary Center Tap Output 0.05 KVA Condition Monitoring, Secondary Center Tap Output 0.05 KVA Procurement, Secondary Center Tap Output 0.05 KVA Noise Reduction, Secondary Center Tap Output 0.05 KVA Compatibility, Secondary Center Tap Output 0.05 KVA Integration, Secondary Center Tap Output 0.05 KVA Ratings, Secondary Center Tap Output 0.05 KVA Use Cases, Secondary Center Tap Output 0.05 KVA Field Services, Secondary Center Tap Output 0.05 KVA Innovation in Design, Secondary Center Tap Output 0.05 KVA Quick Deployment, Secondary Center Tap Output 0.05 KVA Custom Solutions, Secondary Center Tap Output 0.05 KVA Portable Solutions