DELTA WYE TRANSFORMER
0.1 KVA, 60 HZ, P/N 9360L
Specifications:
- Isolation Transformer, 0.1 KVA, 3 PH, 60 Hz, P/N 9360L
- Primary: 208 VAC L-L, 0.277 Amps, Delta
- Secondary: 208 VAC L-L, 120 VAC L-N, 0.277 Amps, Wye with Neutral (N)
- Copper windings
- Approvals: none
- Primary and secondary connections are solder lugs
- Open core and coil: 4″H x 6″W x 4″D approximately
- The unit can be secured by clamping the C cores
- Estimated weight: TBD
The photo of the transformer is shown below:
The schematic diagram is shown below:
To discuss your specific application, please call our phone number at (714) 624-4740, or send us an email at quote@lcmagnetics.com.
Small Wye Delta transformers, Small Wye-Wye transformers, 0.1 KVA Delta Wye transformers, 0.1 KVA Wye Delta transformers, 0.1 KVA Wye-Wye transformers, 0.1 KVA 400 Hz 3 PH transformers, delta wye transformer, 0.1 KVA delta wye transformer, 60 Hz delta wye transformer, P/N 9360L transformer